{"id":4722,"date":"2022-10-28T09:28:50","date_gmt":"2022-10-28T07:28:50","guid":{"rendered":"https:\/\/merytronic.gorlan.com\/recomendaciones-de-uso-ariadna-ci\/"},"modified":"2022-11-02T12:11:10","modified_gmt":"2022-11-02T10:11:10","slug":"recommendations-use-ariadna-ci","status":"publish","type":"post","link":"https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/","title":{"rendered":"Recommendations for the use of Ariadna CI"},"content":{"rendered":"<h2><\/h2>\n<h2>Electric Cable Identification<\/h2>\n<p>In <strong>electrical maintenance works<\/strong>, in order to cope with safety standards, it becomes necessary\u00a0<strong>to identify correct cable unambiguously prior to its manipulation.<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" width=\"250\" height=\"167\" class=\"size-medium wp-image-2905 alignleft\" src=\"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/06\/ariadna-ci-250x167.jpg\" alt=\"Identificador de Cables\" srcset=\"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/06\/ariadna-ci-250x167.jpg 250w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/06\/ariadna-ci-700x467.jpg 700w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/06\/ariadna-ci-768x512.jpg 768w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/06\/ariadna-ci-120x80.jpg 120w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/06\/ariadna-ci.jpg 960w\" sizes=\"(max-width: 250px) 100vw, 250px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>The\u00a0<strong>Ariadna CI<\/strong>\u00a0\u2013 Cable Identifier is an advanced, yet simple to operate, digital tool. It helps users to\u00a0<strong>easily identify any de-energized electric cables, energized MV cables and energized\u00a0 LV cables,<\/strong>\u00a0among multiple conductors, in trenches, manholes, panels, aerial\/underground conversions, etc.<\/p>\n<p>This article contains a series of recommendations for the use of this device.<\/p>\n<p>&nbsp;<\/p>\n<h3><\/h3>\n<h2>Recommendation 1. The correct cable identification<\/h2>\n<p><span class=\"TextRun SCXW70731089 BCX0\" lang=\"EN-GB\" xml:lang=\"EN-GB\" data-contrast=\"none\"><span class=\"NormalTextRun SCXW70731089 BCX0\">How is it displayed on the receiver (CI-Rx) that the CORRECT cable identification is?<\/span><\/span><span class=\"EOP SCXW70731089 BCX0\" data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335551550&quot;:6,&quot;335551620&quot;:6,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-4727 \" src=\"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/cable-return-identification.jpg\" alt=\"cable return identification\" width=\"744\" height=\"239\" srcset=\"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/cable-return-identification.jpg 1084w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/cable-return-identification-250x80.jpg 250w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/cable-return-identification-700x225.jpg 700w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/cable-return-identification-768x247.jpg 768w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/cable-return-identification-120x39.jpg 120w\" sizes=\"(max-width: 744px) 100vw, 744px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2>Recommendation 2. Repeat measurements<\/h2>\n<p><span class=\"TextRun SCXW124108521 BCX0\" lang=\"EN-GB\" xml:lang=\"EN-GB\" data-contrast=\"none\"><span class=\"NormalTextRun SCXW124108521 BCX0\">Once the device has been connected, <strong>carry out a first identification inside the Transformer Substation<\/strong>. The same reading should be obtained in the tasting.<\/span><\/span><span class=\"EOP SCXW124108521 BCX0\" data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335551550&quot;:6,&quot;335551620&quot;:6,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-4730 \" src=\"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/cable-trench-identification.jpg\" alt=\"cable trench identification\" width=\"725\" height=\"260\" srcset=\"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/cable-trench-identification.jpg 985w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/cable-trench-identification-250x90.jpg 250w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/cable-trench-identification-700x251.jpg 700w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/cable-trench-identification-768x275.jpg 768w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/cable-trench-identification-120x43.jpg 120w\" sizes=\"(max-width: 725px) 100vw, 725px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2>Recommendation 3. Correct fitting of the induction clamp<\/h2>\n<ul>\n<li>Place the <strong>clamp fully closed<\/strong> until the induction buzzing sound is heard.<\/li>\n<li>The clamp must be positioned <strong>clamped only on the low voltage cable<\/strong>, outside the shielding and the capacitive conductor.\u00a0<span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335551550&quot;:6,&quot;335551620&quot;:6,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-4704 alignleft\" src=\"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/tip-3.jpg\" alt=\"Ariadna CI colocaci\u00f3n pinza\" width=\"517\" height=\"294\" srcset=\"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/tip-3.jpg 677w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/tip-3-250x142.jpg 250w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/tip-3-120x68.jpg 120w\" sizes=\"(max-width: 517px) 100vw, 517px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2>Recommendation 4. Direct connection<\/h2>\n<p>It is recommended, whenever possible, to use the &#8220;direct connection&#8221; mode.<\/p>\n<p>Advantages<\/p>\n<ul>\n<li>Measurement of impedance (\u03a9) and injected signal (mA)<\/li>\n<li>Best performance, up to 2k\u03a9 (with clamp: 10 \u03a9)<\/li>\n<li>Long distances &lt;50km<\/li>\n<\/ul>\n<p>Disadvantages<\/p>\n<ul>\n<li>TWO tests are needed to perform phase identification (with induction clamp only ONE)<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-4705 \" src=\"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/tip-4-700x525.jpg\" alt=\"Conexi\u00f3n directa Ariadna CI\" width=\"523\" height=\"392\" srcset=\"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/tip-4-700x525.jpg 700w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/tip-4-250x187.jpg 250w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/tip-4-768x576.jpg 768w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/tip-4-1536x1152.jpg 1536w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/tip-4-2048x1536.jpg 2048w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/tip-4-120x90.jpg 120w\" sizes=\"(max-width: 523px) 100vw, 523px\" \/><\/p>\n<p>&nbsp;<\/p>\n<h2>Recommendation 5. Quick direct connection method<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-4707 size-medium alignright\" src=\"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/tip-5-250x333.jpg\" alt=\"Conexi\u00f3n directa en botellas\" width=\"195\" height=\"300\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>The picture shows a quick way of direct connection of the Ariadna CI without the need to open the bottles.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2>Recommendation 6. Energized cables identification<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" width=\"250\" height=\"250\" class=\"size-medium wp-image-3912 alignleft\" src=\"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/09\/cables-a-identificar-250x250.jpg\" alt=\"cables a identificar\" srcset=\"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/09\/cables-a-identificar-250x250.jpg 250w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/09\/cables-a-identificar-150x150.jpg 150w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/09\/cables-a-identificar-120x120.jpg 120w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/09\/cables-a-identificar.jpg 400w\" sizes=\"(max-width: 250px) 100vw, 250px\" \/><\/p>\n<p>Advantages:<\/p>\n<ul>\n<li>Use the Ariadna CI in mode: LIVED MV CABLE IDENTIFICATION\u00a0 (or LV).<\/li>\n<li>Identify the cable in service.<\/li>\n<li>Request line clearance (less clearance time, less impact on consumers).<\/li>\n<li>Re-identify the cable WITHOUT VOLTAGE, in a FAST, SAFE AND RELIABLE way.<\/li>\n<\/ul>\n<p><span style=\"color: #000080;\"><a style=\"color: #000080;\" href=\"https:\/\/merytronic.gorlan.com\/en\/advantages-identify-live-electrical-cables\/\">In this article we explain the advantages in more detail.<\/a><\/span><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>If you want to know more about our solutions for the identification of live and dead cables, click on the banner.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/merytronic.gorlan.com\/en\/product-category\/electrical-safety\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-4794 size-full\" src=\"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/Ariadna-CI-banner-new-1.jpg\" alt=\"Identificaci\u00f3n de cable\" width=\"800\" height=\"200\" srcset=\"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/Ariadna-CI-banner-new-1.jpg 800w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/Ariadna-CI-banner-new-1-250x63.jpg 250w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/Ariadna-CI-banner-new-1-700x175.jpg 700w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/Ariadna-CI-banner-new-1-768x192.jpg 768w, https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/Ariadna-CI-banner-new-1-120x30.jpg 120w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"Electric Cable Identification In electrical maintenance works, in order to cope with safety standards, it becomes necessary\u00a0to identify correct cable unambiguously prior to its manipulation. &nbsp; The\u00a0Ariadna CI\u00a0\u2013 Cable Identifier is an advanced, yet simple to operate, digital tool. It helps users to\u00a0easily identify any de-energized electric cables, energized MV cables and energized\u00a0 LV cables,\u00a0among&#8230; <a class=\"view-article\" href=\"https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/\">View Article<\/a>","protected":false},"author":6,"featured_media":4719,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[58,76],"tags":[261,264,262,263,265],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v21.3 (Yoast SEO v22.5) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Recommendations for the use of Ariadna CI | Merytronic<\/title>\n<meta name=\"description\" content=\"Recommendations for the use of Ariadna CI. In electrical maintenance works, it becomes necessary\u00a0to identify correct cable unambiguously prior to its manipulation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Recommendations for the use of Ariadna CI\" \/>\n<meta property=\"og:description\" content=\"Recommendations for the use of Ariadna CI. In electrical maintenance works, it becomes necessary\u00a0to identify correct cable unambiguously prior to its manipulation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/\" \/>\n<meta property=\"og:site_name\" content=\"Merytronic\" \/>\n<meta property=\"article:published_time\" content=\"2022-10-28T07:28:50+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-11-02T10:11:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/Tips-articulo-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1892\" \/>\n\t<meta property=\"og:image:height\" content=\"1015\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Maria Gomez (MRT)\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Maria Gomez (MRT)\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Recommendations for the use of Ariadna CI | Merytronic","description":"Recommendations for the use of Ariadna CI. In electrical maintenance works, it becomes necessary\u00a0to identify correct cable unambiguously prior to its manipulation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/","og_locale":"en_US","og_type":"article","og_title":"Recommendations for the use of Ariadna CI","og_description":"Recommendations for the use of Ariadna CI. In electrical maintenance works, it becomes necessary\u00a0to identify correct cable unambiguously prior to its manipulation.","og_url":"https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/","og_site_name":"Merytronic","article_published_time":"2022-10-28T07:28:50+00:00","article_modified_time":"2022-11-02T10:11:10+00:00","og_image":[{"width":1892,"height":1015,"url":"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/Tips-articulo-2.jpg","type":"image\/jpeg"}],"author":"Maria Gomez (MRT)","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Maria Gomez (MRT)","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/#article","isPartOf":{"@id":"https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/"},"author":{"name":"Maria Gomez (MRT)","@id":"https:\/\/merytronic.gorlan.com\/#\/schema\/person\/2ec54744fc8d0acdeedb5ac6f572397e"},"headline":"Recommendations for the use of Ariadna CI","datePublished":"2022-10-28T07:28:50+00:00","dateModified":"2022-11-02T10:11:10+00:00","mainEntityOfPage":{"@id":"https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/"},"wordCount":348,"commentCount":0,"publisher":{"@id":"https:\/\/merytronic.gorlan.com\/#organization"},"image":{"@id":"https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/#primaryimage"},"thumbnailUrl":"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/Tips-articulo-2.jpg","keywords":["Ariadna CI","cable identifier","Identificaci\u00f3n cable","recomendaciones uso","recommendations"],"articleSection":["Products","Technical articles"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/","url":"https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/","name":"Recommendations for the use of Ariadna CI | Merytronic","isPartOf":{"@id":"https:\/\/merytronic.gorlan.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/#primaryimage"},"image":{"@id":"https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/#primaryimage"},"thumbnailUrl":"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/Tips-articulo-2.jpg","datePublished":"2022-10-28T07:28:50+00:00","dateModified":"2022-11-02T10:11:10+00:00","description":"Recommendations for the use of Ariadna CI. In electrical maintenance works, it becomes necessary\u00a0to identify correct cable unambiguously prior to its manipulation.","breadcrumb":{"@id":"https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/#primaryimage","url":"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/Tips-articulo-2.jpg","contentUrl":"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/10\/Tips-articulo-2.jpg","width":1892,"height":1015,"caption":"Cable Identifier Ariadna CI"},{"@type":"BreadcrumbList","@id":"https:\/\/merytronic.gorlan.com\/en\/recommendations-use-ariadna-ci\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Products","item":"https:\/\/merytronic.gorlan.com\/en\/category\/products\/"},{"@type":"ListItem","position":2,"name":"Recommendations for the use of Ariadna CI"}]},{"@type":"WebSite","@id":"https:\/\/merytronic.gorlan.com\/#website","url":"https:\/\/merytronic.gorlan.com\/","name":"Merytronic","description":"Mapeado de redes el\u00e9ctricas de distribuci\u00f3n","publisher":{"@id":"https:\/\/merytronic.gorlan.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/merytronic.gorlan.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/merytronic.gorlan.com\/#organization","name":"Merytronic","url":"https:\/\/merytronic.gorlan.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/merytronic.gorlan.com\/#\/schema\/logo\/image\/","url":"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/02\/resultado_defecto_merytronic.jpg","contentUrl":"https:\/\/merytronic.gorlan.com\/wp-content\/uploads\/2022\/02\/resultado_defecto_merytronic.jpg","width":944,"height":629,"caption":"Merytronic"},"image":{"@id":"https:\/\/merytronic.gorlan.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/merytronic.gorlan.com\/#\/schema\/person\/2ec54744fc8d0acdeedb5ac6f572397e","name":"Maria Gomez (MRT)","url":"https:\/\/merytronic.gorlan.com\/en\/author\/mgogorlan-com\/"}]}},"_links":{"self":[{"href":"https:\/\/merytronic.gorlan.com\/en\/wp-json\/wp\/v2\/posts\/4722"}],"collection":[{"href":"https:\/\/merytronic.gorlan.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/merytronic.gorlan.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/merytronic.gorlan.com\/en\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/merytronic.gorlan.com\/en\/wp-json\/wp\/v2\/comments?post=4722"}],"version-history":[{"count":9,"href":"https:\/\/merytronic.gorlan.com\/en\/wp-json\/wp\/v2\/posts\/4722\/revisions"}],"predecessor-version":[{"id":4797,"href":"https:\/\/merytronic.gorlan.com\/en\/wp-json\/wp\/v2\/posts\/4722\/revisions\/4797"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/merytronic.gorlan.com\/en\/wp-json\/wp\/v2\/media\/4719"}],"wp:attachment":[{"href":"https:\/\/merytronic.gorlan.com\/en\/wp-json\/wp\/v2\/media?parent=4722"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/merytronic.gorlan.com\/en\/wp-json\/wp\/v2\/categories?post=4722"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/merytronic.gorlan.com\/en\/wp-json\/wp\/v2\/tags?post=4722"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}